Home Ventilation installation
Home ventilation installation
Streaming windows and black mould usually mean wet air has nowhere to go. Here is how extractor fans, PIV and MVHR differ, what each costs, and which one suits your home.
Home ventilation installation covers three main jobs: extractor fans that pull wet air out of kitchens and bathrooms, positive input ventilation (PIV) that pushes filtered air in from the loft, and mechanical ventilation with heat recovery (MVHR) that swaps stale air for fresh air through ducts while keeping most of the heat. The right one depends on how airtight your home is and where the moisture comes from.
We don’t install ventilation ourselves. Tell us about your home and the problem, and we pass your request to ventilation installers and electricians who cover your postcode.
Signs your home needs better ventilation
- windows streaming with water every winter morning, especially in bedrooms
- black mould in ceiling corners, behind wardrobes or around window reveals
- a bathroom mirror that stays fogged long after a shower
- a musty smell, or cooking smells that linger into the next day
- condensation that got worse after new double glazing went in
That last one catches many people out. Approved Document F says replacing windows is likely to make a home more airtight, which can cut useful ventilation. Wet air that used to leak out through draughty frames now stays in and settles on the coldest surfaces. Our guide on how to stop window condensation covers the day-to-day fixes.
Extractor fans, PIV and MVHR compared
| System | How it works | Best for | Disruption |
|---|---|---|---|
| Extractor fan | Pulls wet air out of one room to outside | Bathrooms, kitchens, utility rooms | Low: a core hole or a duct through the ceiling |
| PIV | Fan in the loft blows filtered air into the house, pushing damp air out through gaps | Older, leaky houses with condensation | Low: one unit in the loft and a ceiling diffuser |
| MVHR | Extracts from wet rooms, supplies fresh air to living rooms, swaps heat between the two | New builds, airtight homes, deep retrofits | High: ducts to most rooms, boxing-in |
Extractor fans
A working extractor fan is the first fix for a damp bathroom or kitchen. Approved Document F sets minimum intermittent extract rates: 15 litres per second for a bathroom, 30 l/s for a kitchen with a cooker hood that vents outside, 60 l/s for a kitchen without one, and 30 l/s for a utility room. Many cheap fans fall short once you add a long or crushed duct.
MyJobQuote puts a like-for-like bathroom fan swap at £80 to £150 and a new ceiling fan ducted through the loft at £350 to £600, with an average new install of around £300 in 2026.
Common faults an installer will look for:
- a fan ducted into the loft instead of outside, or no duct attached at all
- a long flexible duct with sags that collect water and cut airflow
- no overrun timer or humidistat, so the fan stops as soon as the light goes off
- a fan too small for the room, or sitting far from the shower
Swapping an old fan for a new one on the same cabling doesn’t need to be notified to building control, according to Approved Document F. GOV.UK lists any new circuit from the fuse box as notifiable work, so a new fan on its own circuit needs a registered electrician or a building control application. Ask for a certificate.
Positive input ventilation (PIV)
A PIV unit sits in the loft and runs all the time, drawing air from the roof space, filtering it and blowing it gently into the house through a ceiling diffuser, usually on the landing. The slight positive pressure pushes stale, damp air out through the gaps in the building. MyBuilder puts the unit at about £250 to £850 and a typical installed system at £400 to £1,200.
PIV is popular with landlords and owners of older houses because it goes in quickly with little mess. The usual complaint is a cool draught near the diffuser in winter, which a model with a small heater or temperature control can reduce. Flats without a loft can use wall-mounted versions.
MVHR
MVHR extracts air from kitchens and bathrooms and supplies fresh, filtered air to bedrooms and living rooms. The two streams pass through a heat exchanger, so incoming air is warmed by the outgoing air. MyJobQuote puts the average installed cost at £6,900, with a typical range of £3,500 to £12,000 depending on house size and how hard it is to run ducts.
Before you commit, know what MVHR is not:
- It is not air conditioning. A summer bypass lets cooler night air in, but it won’t cool a hot room the way a split system does. For that, see air conditioning installation.
- It doesn’t work well with windows open. The heat recovery is lost.
- It needs upkeep. Filters need changing every six to twelve months, and MyJobQuote puts an annual service at £100 to £300.
MVHR pays back best in an airtight home. In a draughty older house, much of the air bypasses the unit through gaps, so PIV or good extract fans may do the job for far less.
How a ventilation install works
- Survey. The installer looks at where the moisture comes from, checks existing fans and ducts, and looks in the loft.
- Design. For MVHR, someone should size the system and plan duct runs to each room. Expect design to be a separate line.
- Fitting. An extractor fan or PIV unit is usually a few hours. MVHR in an existing home can take several days.
- Commissioning. The installer measures the airflow at each fan or valve and records it. Approved Document F expects air flow rates to be recorded in litres per second.
Rules and who to use
Most fan and PIV work involves electrics, so use an electrician registered with a competent person scheme such as NICEIC or NAPIT, who can self-certify. For MVHR, ask whether the installer has fitted and commissioned similar systems and will hand over the airflow readings. When you replace windows, Approved Document F says new windows should keep any existing trickle vents and the overall ventilation should be no worse than before.
Landlords have a duty to keep homes free of serious damp and mould hazards. Since 27 October 2025, social landlords in England must investigate significant damp and mould within 10 working days under Awaab’s Law. See our damp and mould removal page for more on landlord duties.
Comparing ventilation quotes
- Does the quote name the make, model and the extract or supply rate the unit will deliver?
- Is the duct route and length stated, and does it vent outside?
- Are controls included: humidistat, overrun timer, boost switch?
- For MVHR, are design, commissioning and the first set of filters listed?
- Is making good, such as boxing-in and decorating, included or excluded?
A quote that offers MVHR to fix one damp bathroom is probably oversold. A quote that offers only a dehumidifier for a whole-house problem is probably undersold.
Typical ventilation prices
| Job | Typical UK price | Notes |
|---|---|---|
| Bathroom extractor fan, like-for-like replacement | £80 to £150 | One to two hours on the existing cabling and duct |
| New window extractor fan | £150 to £300 | Two to six hours |
| New wall or ceiling fan ducted through an outside wall | £250 to £450 | Four to eight hours |
| New ceiling fan ducted through the loft | £350 to £600 | About a day |
| PIV unit, supplied and fitted | £400 to £1,200 | Unit alone £250 to £850; heaters and smart controls cost more |
| MVHR, one or two bed flat | £2,500 to £5,000 | Supply and fit |
| MVHR, three bed house | £4,000 to £8,000 | Higher for retrofit with awkward duct runs |
| MVHR, four or five bed detached | £8,000 to £12,000 | Difficult retrofits can go higher |
| MVHR design | £300 to £700 | Often a separate line on the quote |
| MVHR commissioning | £300 to £800 | Airflow balancing at each valve |
| MVHR annual service | £100 to £300 | Replacement filters £15 to £120 |
Sources: MyJobQuote extractor fan cost guide (September 2026) and heat recovery cost guide (October 2026), MyBuilder PIV price guide and Trade2Base MVHR installation costs (2026). Prices vary by region and access, and London and the South East are usually dearer.
Ventilation installation by city
Show all 50 cities as a list
England
- Birmingham
- Bolton
- Bournemouth
- Bradford
- Brighton
- Bristol
- Cambridge
- Chelmsford
- Coventry
- Derby
- Doncaster
- Exeter
- Gloucester
- Huddersfield
- Hull
- Ipswich
- Leeds
- Leicester
- Liverpool
- London
- Luton
- Manchester
- Middlesbrough
- Milton Keynes
- Newcastle
- Northampton
- Norwich
- Nottingham
- Oxford
- Peterborough
- Plymouth
- Portsmouth
- Preston
- Reading
- Sheffield
- Southampton
- Stoke-on-Trent
- Sunderland
- Swindon
- Wakefield
- Warrington
- Wolverhampton
- York
Northern Ireland
Common questions
Is PIV or MVHR better for condensation?
PIV is cheaper and quicker to fit, often in a few hours in the loft, and suits an older, leaky house with a condensation problem. MVHR recovers heat and gives better control, but it needs ducts to every room and works best in an airtight home. In a small semi with streaming windows, PIV is usually the first thing to try.
How much does MVHR cost to run?
Golding Homes, a housing association, tells its tenants an MVHR system costs around £35 to £75 a year in electricity to run constantly. Your figure depends on the unit, fan speed and tariff. Replacement filters cost about £15 to £120 and are changed every six to twelve months.
What size extractor fan does a bathroom need?
Approved Document F sets a minimum intermittent extract rate of 15 litres per second for a bathroom, 30 l/s for a kitchen with a cooker hood that vents outside, 60 l/s for a kitchen without one, and 30 l/s for a utility room. The fan has to achieve that rate once ducted, not just on the box.
Do I need building regulations approval for an extractor fan?
Replacing an extractor fan or cooker hood that uses the existing cabling does not need to be notified to building control, according to Approved Document F. A new fan on a new circuit, or ventilation as part of a bigger job, may need to be. Your installer should tell you which applies.
Does PIV blow cold air?
Some people notice a cool draught near the diffuser in winter. Many units have a small heater or temperature control to temper the incoming air. Placing the diffuser on a landing rather than above a seat also helps.
Will new windows make condensation worse?
They can. Approved Document F says replacing windows is likely to make a home more airtight, so the new windows should keep any existing trickle vents and the overall ventilation should be no worse than before. Ask your window fitter about background ventilators before the order goes in.
Sources
- GOV.UK: Approved Document F, ventilation (2021 edition, Volume 1)
- MyJobQuote: installing a heat recovery system cost (October 2026)
- Trade2Base: MVHR installation costs UK
- MyJobQuote: bathroom extractor fan installation cost (September 2026)
- MyBuilder: PIV installation cost guide
- Golding Homes: your MVHR system
- GOV.UK: building work, replacements and repairs to your home
- Which?: how to stop condensation